N/A
N=110
Ultrasound Prediction of Prolonged Labour
Prolonged Labor
Bottom Line
View on ClinicalTrials.gov: NCT00915148 ↗Enrolled (actual)
110
Serious AEs
0.0%
Results posted
Apr 2016
Primary outcome: Primary: Area Under the Receiver Operating Curve (ROC AUC) Values for Prediction of Vaginal Delivery Using 2D or 3D Ulrasound — 81; 76; 80; 76 percentage probability — p=<0.01
Study Design & Population
- Study type
- Observational
- Phase
- N/A
- Interventions
- Ultrasound examination (Other)
- Age
- Pediatric, Adult, Older Adult
- Sex
- Female
- Sponsor
- Helse Stavanger HF
- Primary completion
- Aug 2010
Outcome Measures
| Outcome | Result | p-value |
|---|---|---|
| PRIMARY Area Under the Receiver Operating Curve (ROC AUC) Values for Prediction of Vaginal Delivery Using 2D or 3D Ulrasound |
81; 76; 80; 76 | <0.01 sig |
| SECONDARY Percentage of Women With Delivery Within 6 Hours From Defined Prolonged Labor (in Accordance With WHO Recommendations) |
74; 39; 72; 44 | <0.01 sig |
Summary
This observational study is designed to correlate findings on ultrasound with manual palpation, and to consider if delivery outcome can be predicted with help of ultrasound. Specifically, the study will evaluate the significance of fetal head level (descent) in the pelvis, measured with ultrasound.
Eligibility Criteria
Inclusion Criteria
- Primi gravidae
- >37th week
- Cephalic presentation
- Prolonged first stage according to WHO definitions.
Exclusion Criteria
- Multiple pregnancies
- Intrauterine fetal death
Data sourced from ClinicalTrials.gov (NCT00915148). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication.