Mode
Text Size
Log in / Sign up
N/A N=50

TUI 3D in Diagnosis of Placenta Accreta: Comparison With Gray-scale and Color Doppler Techniques

Placenta Accreta

Enrolled (actual)
50
Serious AEs
0.0%
Results posted
Apr 2017
Primary outcome: Primary: Loss of the Retro Placental Sonolucent Zone by 2D Grayscale Ultrasonography — 12; 19 participants

Study Design & Population

Study type
Observational
Phase
N/A
Interventions
Age
Adult · 20+ yrs
Sex
Female
Sponsor
Ain Shams University
Primary completion
Feb 2016

Outcome Measures

OutcomeResultp-value
PRIMARY
Loss of the Retro Placental Sonolucent Zone by 2D Grayscale Ultrasonography
12; 19
PRIMARY
Abnormal Placental Lacunae by 2D Grayscale Ultrasonography
19; 15
SECONDARY
Crowded Vessels Over Peripheral Sub-placental Zone by Power Doppler Ultrasonography
8; 18
SECONDARY
Abnormal Placental Lacunae by Power Doppler Ultrasonography
20; 13
SECONDARY
Crowded Vessels Over Peripheral Sub-placental Zone by 3D Tomographic Ultrasound Imaging (TUI)
7; 18
SECONDARY
Abnormal Placental Lacunae by 3D Tomographic Ultrasound Imaging (TUI)
19; 13

Summary

The purpose of this study is to evaluate the potential of the 3 D TUI view in diagnosis of morbidly adherent placenta in comparison to 2D grayscale, color Doppler and intraoperative findings.

Eligibility Criteria

Inclusion Criteria

  • History of previous cesarean section or hysterotomy.
  • Placenta previa with its lower edge covering the scar of previous cesarean section
  • From 28 wks to Full term.

Exclusion Criteria

  • Multiple pregnancies.
  • Medical disorder as diabetes mellitus, hypertension.
  • Obese patients. BMI > 30
  • Intrauterine growth retardation.
View full record on ClinicalTrials.gov →

Data sourced from ClinicalTrials.gov (NCT02712099). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication.

Back to search