N/A
N=293
Mu-Opioid Receptor Genetic Polymorphism and Intrathecal Analgesia
Labor Pain · Post-cesarean Delivery
Bottom Line
View on ClinicalTrials.gov: NCT00418015 ↗Enrolled (actual)
293
Serious AEs
0.0%
Results posted
Apr 2011
Primary outcome: Primary: Duration of Intrathecal Fentanyl Analgesia — 70; 63 Minutes — p=0.54
Study Design & Population
- Study type
- Observational
- Phase
- N/A
- Interventions
- Blood Draw (Procedure)
- Age
- Adult · 18+ yrs
- Sex
- Female
- Sponsor
- Northwestern University
- Primary completion
- May 2007
Outcome Measures
| Outcome | Result | p-value |
|---|---|---|
| PRIMARY Duration of Intrathecal Fentanyl Analgesia |
70; 63 | 0.54 |
| PRIMARY Duration of Intrathecal Analgesia Following Cesarean Delivery |
26; 40 | 0.15 |
| PRIMARY Visual Analog Pain Scale (0 to 100) at Analgesia Request Following Intrathecal Intervention |
33; 38; 26; 40 | 0.23 |
| SECONDARY Severity of Pruritus Following Fentanyl |
9; 13; 48; 59; 35; 26 | 0.06 |
| SECONDARY Subjects With Pruritus at 24 Hours Post Morphine |
33; 3 | 0.02 sig |
Summary
Pharmacogenetics has allowed clinicians to identify associations between an individual's genetic profile and his/her response to drugs. The A118G (c.188A>G)is a single nucleotide polymorphism (SNP) of the mu-opioid receptor (OPRM1). The mutated protein, N40D, appears to increase the binding affinity and potency of beta-endorphin approximately 3-fold. Individuals carrying the variant receptor gene (A118G) may show differences in some of the functions mediated by beta-endorphin action at the altered OPRM1. Combined spinal-epidural (CSE) analgesia is a commonly utilized technique for labor analgesia. Analgesia is initiated with the intrathecal administration of a lipid-soluble opioid (e.g. fentanyl), sometimes combined with a local anesthetic. The mean (± SD) duration of analgesia after intrathecal fentanyl 25 microgram was 89 ± 43 min. The ED50 of intrathecal fentanyl for labor analgesia varies between 14 microgram to 18.2 microgram. The wide variability in the duration of analgesia, as was well the differences in ED50 may result from differences known to affect labor pain (e.g., ethnicity, parity, stage of labor). Another possible explanation for the differences in opioid requirements and duration, as well as incidence of side effects such as itching and nausea/vomiting, is that opioid responsiveness is determined by genetic variability of the µ-opioid receptor. The ED50 for intrathecal fentanyl labor analgesia was significantly lower for parturients carrying the A118G variant of the mu-opioid receptor, compared to parturients with the A118 wild type receptor. The purpose of this study is to determine whether polymorphism at nucleotide 118 of OPRM1 influences the duration of intrathecal opioid (fentanyl) labor analgesia, and intrathecal opioid (morphine) postoperative analgesia.
Eligibility Criteria
Inclusion Criteria
Study 1: Laboring Women
- Nulliparous women in spontaneous labor or with spontaneous rupture of membranes
- Term pregnancy (≥ 37 weeks gestation)
- Vertex presentation
- Healthy, ASA PS 1-2
- Desire neuraxial labor analgesia.
Study 2: Cesarean Delivery
- Nulliparous women undergoing elective primary Cesarean delivery (e.g., for breech presentation, macrosomia)
- Term pregnancy (≥ 37 weeks gestation)
- Healthy, ASA PS 1-2
- Desired spinal anesthesia.
Exclusion Criteria
Study 1: Laboring Women
- Chronic or pregnancy induced disease
- Chronic opioid use
- History of substance abuse
- Systemic opioid analgesia before initiation of neuraxial labor analgesia
- Cervical dilation 5 cm of time of request for neuraxial analgesia
- Allergy to fentanyl
Study 2: Cesarean delivery
- Chronic or pregnancy induced disease
- Chronic opioid use
- Previous abdominal or pelvic surgery
- Allergy to fentanyl, morphine, or bupivacaine
- BMI ≥ 40 kg/m2
- History of substance abuse
- Failed spinal anesthesia
- Requirement for systemic opioid supplementation during Cesarean delivery.
Data sourced from ClinicalTrials.gov (NCT00418015). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication.