N/A
Completed N=458
Randomized MicroPort's Firehawk DES Versus Xience V: TARGET I Trial
Source: ClinicalTrials.gov NCT01196819 ↗Enrolled (actual)
458
Serious AEs
16.4%
Results posted
Feb 2018
Primary outcomePrimary: 9 Months In-stent Late Lumen Loss — 0.13; 0.13 mm — p=0.94
Summary
The purpose of this study is to evaluate new generation drug eluting stent (DES) of MicroPort of its safety, efficacy and delivery system in treating CAD.
Outcome Measures
| Outcome | Result | p-value |
|---|---|---|
| PRIMARY 9 Months In-stent Late Lumen Loss |
0.13; 0.13 | 0.94 |
| SECONDARY 9 Months In-stent Diameter Stenosis |
11.51; 11.85 | 0.69 |
| SECONDARY Target Lesion Failure(TLF) Rate |
2.2; 2.2 | 1.0 |
| SECONDARY TLF(Target Lumen Failure) Rate |
3.51; 4.05 | 0.76 |
| SECONDARY TLF(Target Lumen Failure) |
6.67; 5.99 | 0.77 |
| SECONDARY Number of Participants With Stent Thrombsis (ARC Defined Definite/Probable) |
1; 0 | — |
Eligibility Criteria
Inclusion Criteria
- Age 18-75, male or women who are not pregnant
- Evidence of non-symptomatic ischemia, stable or non-stable angina or past heart attack cases
- Target lesion is primary, single artery and single lesion of coronary artery
- Target lesion vessel length ≤24mm, diameter 2.25mm-4.0mm
- Lesion diameter stenosis ≥70%
- Candidates understand the study, willing to sign Consent of Agreement and to willing to accept follow-up For long lesion group, at least one target lesion length ≥28mm,diameter 2.5mm-4.0mm, and one lesion needs to implant 33mm 0r 38mm long stent
Exclusion Criteria
- Acute heart attack within one week
- Chronic complete stenosis (TIMI 0), left main lesion, three branches need to treat, branch vessel diameter ≤2.5mm and bypass lesion
- Calcified lesion failed in pre-dilation and twisted lesion
- In-stent restenosis
- Stent implanted within one year
- Severe heart failure (NYHA above III) or left ventricle EF 2.0mg/dl
- Bleeding risk; allergic to drugs and agents used in procedure/treatment
- Life expectation < 12 months
- No compliances to the protocol
- Heart implantation cases
Pre-specified OCT inclusion/exclusion criteria:
- Patients underwent 9-month angio F/U
- No binary restenosis at 9-month
- LLL between -0.01~0.2mm
- No mix-implanted stent
- No more than one bail-out stent
- No TLR occurred at 3 years after PCI
- The target vessel able to deliver the OCT catheter
Data sourced from ClinicalTrials.gov (NCT01196819). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication. Informational only — not medical advice.