N/A
Completed N=40
Sequential Compression Device on Body Temperature
Hypothermia
Source: ClinicalTrials.gov NCT01508052 ↗
Enrolled (actual)
40
Serious AEs
0.0%
Results posted
May 2014
Primary outcomePrimary: Core Body Temperature — 36.4; 36.3; 35.7; 35.6 degree C
Summary
We hypothesized that sequential compression device (SCD) compression system might induce more decreases on core temperature by increasing lower extremity blood flow. And, this study investigated the effects of SCD compression system on body temperature in patients during total intravenous anesthesia (TIVA) with propofol and remifentanil.
Outcome Measures
| Outcome | Result | p-value |
|---|---|---|
| PRIMARY Core Body Temperature |
36.4; 36.3; 35.7; 35.6 | — |
Eligibility Criteria
Inclusion Criteria
- ASA I or II
- 20-65 year
- patient who undergoing elective thyroidectomy
Exclusion Criteria
- coronary occlusive disease
- peripheral vascular disease
- BMI > 30 kg/m2
- abnormal thyroid function test
- laparoscopic assisted thyroidectomy
Data sourced from ClinicalTrials.gov (NCT01508052). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication. Informational only — not medical advice.