N/A
Completed N=33
Analysis of the Eye in Patients With Primary Open-Angle Glaucoma and a Visual Field Defect in One Eye
Source: ClinicalTrials.gov NCT02622191 ↗Enrolled (actual)
33
Serious AEs
0.0%
Results posted
Feb 2019
Primary outcomePrimary: Lamina Cribrosa (Boundaries of the Retinal Layers) Measurements — 264.3; 273.3; 276.2 micro-ohms
Summary
The study aims to further understand glaucoma pathogenesis and progression by utilizing enhanced depth imaging optical coherence tomography to visualize and measure lamina cribrosa in vivo and segmentation technology to accurately delineate and measure boundaries of the retinal layers. Investigators will elaborate further on key concepts of lamina cribrosa thickness and trans-synaptic degeneration.
Outcome Measures
| Outcome | Result | p-value |
|---|---|---|
| PRIMARY Lamina Cribrosa (Boundaries of the Retinal Layers) Measurements |
264.3; 273.3; 276.2 | — |
Eligibility Criteria
Inclusion Criteria
- Best-corrected visual acuity of 20/40 or better
- No media opacities
- Spherical equivalent refractive errors in a range of -6 to +6 diopters
- Cylinder correction within 3.0 diopters.
Exclusion Criteria
- Age +2
- Corneal diseases
- Contact lens use
- History of posterior segment intraocular surgery
- Systemic or ocular diseases that can cause visual field loss.
Data sourced from ClinicalTrials.gov (NCT02622191). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication. Informational only — not medical advice.