30 closest matches · ranked by relevance
Hypoxia
Primary: It Was Expected That the Accuracy Root Mean Square (ARMS) Between Measured SpO2 of Owlet Smart Sock V2 v1.1 and Reference SpO2 Would Meet the Required Specification of…
Healthy
Primary: SpO2 ARMS of Sensor Under Motion Conditions — 1.31 % of oxygen saturated hemoglobin
Sleep Apnea, Obstructive
Primary: Number of Participants With Saturation Pattern Detection (SPD) Indicative of Repetitive Reductions in Air Flow — 4; 0 Participants
Healthy · Hypoxia
Primary: SpO2 Accuracy During Motion Conditions - MaxA Sensor — 1.78 Accuracy Root Mean Square
Hypoxia
Primary: Measure of Accuracy (ARMS [%]) — 2.95 Percentage
Healthy · Hypoxia
Primary: Accuracy of Sensor by Arms Calculation — 1.62; 1.56; 1.48; 1.72 Root Mean Square Error (%)
Healthy
Primary: Accuracy of Sensor by Arms Calculation — 2.0 % of oxygen saturated hemoglobin
Healthy
Primary: Oxygen Saturation (SpO2) Accuracy of Sensor by Arms Calculation During Non-motion — 1.33 % of oxygen saturated hemoglobin
Healthy
Primary: Accuracy of Sensor by Arms Calculation — 1.9 % of oxygen saturated hemoglobin
Healthy
Primary: Oxygen Saturation (SpO2) Accuracy of Sensor — 1.16 % of oxygen saturated hemoglobin
Healthy
Primary: Oxygen Saturation (SpO2) Accuracy of Sensor — 1.99 % of oxygen saturated hemoglobin
Arterial Oxygen Saturation · Healthy
Primary: SpO2 Percentage Specification — 1.8; 1.7; 1.6; 1.7 Percentage of SpO2
Oximetry
Primary: RMSE Compared to CO-oximetry — 2.97; 3.00 RMSE (%)
Healthy · Hypoxia
Primary: Accuracy of Sensor by Arms Calculation — 2.04; 2.11 Root Mean Square Error (%)
Healthy
Primary: Accuracy of Sensor by Arms Calculation — 1.6 % of oxygen saturated hemoglobin
Healthy
Primary: Accuracy of Sensor by Arms Calculation — 1.69 % of oxygen saturated hemoglobin
Hypoxia
Primary: Accuracy of Sensor Oxygen Saturation by Arms Calculation — 0.86 percentage of RMS error
Desaturation of Blood
Primary: Composite Outcome Measure: Successful Capture of Peripheral Capillary Oxygen Saturation (SpO2) Level — 12 participants
Oxygenation
Primary: Tissue Oxygen Saturation (StO2) Measurement on the Extremity With a Radial Arterial Line — 0.68 StO2 percent saturation — p=0.55
Healthy
Primary: Oxygen Saturation (SpO2) Accuracy of Sensor — 1.0 percentage of oxygen saturation
Hypoxia
Primary: SpO2 Accuracy (Arms) of ≤3 Between 70 and 100% — 2.10; 2.19 Percentage
Healthy · Hypoxia
Primary: Accuracy of Sensor by Comparing SpO2 Percent Blood Oxygen Saturation to SaO2 Percent Blood Oxygen Saturation Utilizing Arms Calculation Calculation [Time Frame: 1 - 5…
Healthy
Primary: Accuracy of Red Diamond Disposable Pulse Oximeter Sensor by Arms Calculation — 1.16 percent of oxygen saturated hemoglobin
Healthy
Primary: SpO2 Accuracy of Masimo INVSENSOR00069 — 1.72 % of oxygen saturated hemoglobin
Surgery · Arterial Catheterization, Peripheral
Primary: Oropharyngeal vs Extremity Saturation — 98; 98; 95; 99 percent of oxygen saturation
Arterial Disease
Primary: Evaluate SpO2 Accuracy Per Standards for Pulse Oximetry. — 3.1 percent
Healthy · Hypoxia
Primary: Accuracy of Sensor by Arms Calculation Under Motion Conditions — 2.80; 2.66 Root Mean Square Error (%)
Atelectasis
Primary: Oxygen Requirement to Maintain SpO2>90% — 1; 1; 1; 1 liters per minute
Hypoxia
Primary: Accuracy of Sensor Oxygen Saturation by Arms Calculation — 2.0 percentage of SpO2
Hypoxia
Primary: Accuracy of Sensor Oxygen Saturation by Arms Calculation — 2.0 percentage of SpO2