Ring-augmented gastric bypass shows similar weight loss and safety at one year

Ring-augmented gastric bypass shows similar weight loss and safety at one year
Photo by National Cancer Institute / Unsplash
Key Takeaway
Consider that ring augmentation of OAGB did not improve weight loss or safety at one year; longer-term data are needed.

This randomized controlled trial (RCT) conducted at a single center compared ring-augmented one-anastomosis gastric bypass (OAGB) with conventional OAGB in 214 adult patients eligible for primary OAGB. The study aimed to evaluate short-term outcomes including perioperative safety, adverse events, and weight outcomes at one year. The primary outcome was not explicitly stated, but the analysis focused on these endpoints.

Both groups had a mean operation time of 51 minutes (standard deviation 13 minutes), with no statistically significant difference (p=0.84). Perioperative complication rates were identical: one patient in each group (0.9%) experienced a complication (p=1.00). Postoperative minor complications (Clavien-Dindo grade 1-2) and major complications (grade 3-5) also showed no significant differences (p=0.68 and p=0.77, respectively).

Weight outcomes at one year were comparable between groups. Mean body mass index (BMI) was 28 kg/m2 in both groups. Percent total weight loss (%TWL) was 33% in the ring-augmented group versus 31% in the conventional group (p=0.30). Percent excess weight loss (%EWL) was 86% versus 84% (p=0.45). Neither difference reached statistical significance.

Safety findings were similar. Two Minimizer rings were electively removed at patients' request during the first year, without observed complications related to the ring. No serious adverse events were reported, and tolerability data were not provided.

Compared to prior landmark studies of OAGB, the weight loss results are consistent with expected outcomes for this procedure. However, the addition of a ring did not confer a statistically significant advantage in weight loss at one year. The study is limited by its single-center design and relatively short follow-up of 12 months. Longer-term outcomes are needed to assess durability of weight loss and potential late complications.

Key methodological limitations include the lack of a clearly stated primary outcome, which raises concerns about multiplicity and selective reporting. The study is not powered to detect rare adverse events, and the absence of blinding may introduce bias. Additionally, the generalizability may be limited as all procedures were performed at a single center.

For clinical practice, these results suggest that ring augmentation of OAGB does not improve short-term weight loss or safety compared to conventional OAGB. However, the absence of a statistically significant difference does not prove equivalence. Clinicians should consider that the ring may be removed in some patients, and longer-term data are required before recommending routine use.

Unanswered questions include whether ring augmentation provides any benefit in preventing weight regain or reducing reflux, and whether certain patient subgroups might derive greater benefit. Longer follow-up from this trial and additional studies are needed to clarify the role of ring augmentation in OAGB.

Study Details

Study typeRct
Sample sizen = 214
EvidenceLevel 2
Follow-up12.0 mo
PublishedJan 2026
View Original Abstract ↓
PURPOSE: Recurrent weight gain remains a challenge in metabolic bariatric surgery (MBS). Recent publications focused on ring-augmented Roux-en-Y gastric bypass (RYGB) and ring-augmented sleeve gastrectomy (SG), but few studies have addressed the potential of ring-augmentation for one-anastomosis gastric bypass (OAGB). OBJECTIVES: The RiMini trial is a single-center randomized controlled trial that investigates the difference in long-term weight reduction, associated medical comorbidities, quality of life, and procedure-related adverse events of ring-augmented OAGB compared to conventional OAGB in adult patients eligible for primary OAGB. This analysis reports the trial's short-term outcomes, including the peri-operative safety of the procedure, short-term adverse events, and weight outcomes at one year postoperatively. METHODS: Between July 2022 and December 2023, a total of 214 patients (107 per group) underwent either ring-augmented or conventional OAGB after randomization. Peri- and postoperative adverse events, and total and excess weight loss percentages (%TWL and %EWL) were assessed by intention-to-treat and per-protocol analysis. RESULTS: At baseline, there were no differences between groups regarding age, gender, and body mass index (BMI). Mean operation time was 51 minutes (±13) in both groups (p = 0.84). One patient in each group experienced a perioperative complication (p = 1.00; 0.9%). There was no significant difference in postoperative minor (Clavien Dindo (CD) 1-2) (p = 0.68) or major (CD3-5) (p = 0.77) complications. In the first year, two Minimizer rings were electively removed at patients' request, without observed complications related to the ring. At one year, mean BMI was comparable in both groups (28 kg/m2). There was no statistically significant difference between ring-augmented and conventional OAGB in %TWL (33% vs 31%; p = 0.30), and %EWL (86% vs 84%; p = 0.45). CONCLUSIONS: The 1-year analyses of the RiMini trial showed that ring-augmented OAGB is comparable in safety to conventional OAGB. At 1 year, there was no statistically significant difference in weight loss between the groups.