Mode
Text Size
Log in / Sign up

A smartphone-recorded cry tool may assist in prioritizing clinical monitoring for term newborns with HIENew Tool Aims to Identify Pain in Newborns with HIE

AI-generated summary of the cited source, checked by automated accuracy review. How we work

Key Takeaway
Note that this is a study protocol; results are not yet reported and the tool is not a trigger for cooling.

This study protocol outlines a prospective, single-center diagnostic accuracy and cohort study involving 180 term newborns. The study aims to evaluate the use of smartphone-recorded pain cries following a heel prick to assess Hypoxic Ischemic Encephalopathy (HIE). The primary outcome is the area under the ROC curve of a logistic model using five pre-specified acoustic predictors.

Secondary outcomes include tracking changes in cry acoustics over the first 72 hours of life and assessing associations with clinical severity and short-term outcomes of encephalopathy. The study design includes follow-up at 24 hours, 72 hours, and before discharge. Because this is a protocol, no results or data are currently available.

Clinically, the proposed cry tool is intended to help prioritize EEG, seizure surveillance, closer observation, and referral in low-resource settings. The authors specify that the tool is not intended as a trigger for cooling. As this is a protocol, the evidence is not yet available to support clinical implementation.

Researchers are developing a method to monitor pain in newborn babies who have Hypoxic Ischemic Encephalopathy (HIE). This condition occurs when a baby's brain is damaged due to a lack of oxygen. The study plans to use smartphone recordings of a baby's cry after a heel prick to identify specific sounds related to pain.

The study will involve 180 newborns. This group includes 70 babies with HIE and 110 healthy babies. The goal is to see if the sound of a cry can help doctors identify which babies need the most attention. This is especially useful in areas with limited resources where medical staff may need help prioritizing care.

It is important to note that this is a protocol, which means the study is still in the planning or early stages and results are not yet available. The tool is not intended to decide if a baby needs cooling treatment. It is meant to help doctors decide when to use extra monitoring or refer a baby to a specialist.

What this means for you:
A planned study aims to use smartphone-recorded cries to help identify pain in newborns with brain injuries.

Common questions

What is the goal of using smartphone recordings for newborn cries?

The goal is to create a tool that helps doctors identify pain in newborns with Hypoxic Ischemic Encephalopathy (HIE). This tool is intended to help medical staff prioritize extra monitoring, seizure surveillance, and referrals, especially in settings with limited resources.

Is this tool used to decide on cooling treatments for babies?

No, the tool is not intended to be a trigger for cooling treatment. It is designed to help with monitoring and identifying the need for closer observation or referral for infants with HIE.

Who will be included in this study?

The study plans to include 180 term newborns. This group will consist of 70 babies with HIE and 110 healthy babies who do not have HIE, allowing researchers to compare the sounds of their cries.

Study Details

Study typeMeta analysis
EvidenceLevel 1
PublishedOct 2026
View Original Abstract ↓
Background. Many Indian special newborn care units (SNCUs) cannot offer amplitude-integrated EEG (aEEG) or early MRI, so bedside judgement decides which newborns receive closer neurological attention. Earlier work found that asphyxiated newborns cry with a higher pitch and shorter phonation than healthy newborns, and a meta-analysis reported higher fundamental frequency, dysphonation and atypical melody in infants with neurological dysfunction, with wide differences between studies. Aim. To determine whether basic acoustic features of a smartphone-recorded pain cry (following a heel prick) can differentiate term newborns with HIE from control newborns. Also, to track changes in cry acoustics over the first 72 hours of life and evaluate their association with the clinical severity and short-term outcomes of encephalopathy. Design. A prospective, single centre diagnostic accuracy and cohort study in a tertiary SNCU. Three groups of term newborns are recorded: newborns with HIE, healthy comparators, and sick comparators who do not have HIE. Every newborn is recorded after the same stimulus, the first clinically indicated heel-prick. Newborns with HIE and sick comparators are recorded again at 24 hours, 72 hours and before discharge. A cry that is late or absent counts as a result and not as a missing value. Three clinicians blinded to group also classify the cries by listening, so the phone-based measures can be compared with the human ear. Analysis. The primary outcome is the area under the ROC curve of a logistic model with five pre-specified acoustic predictors. The target is 180 analyzable newborns (70 with HIE and 110 comparators). Reporting follows STARD and TRIPOD+AI. Relevance. In a South Asian trial, cooling did not reduce death or disability at 18 months and increased death alone. A cry tool in this setting is therefore proposed to help prioritize EEG, seizure surveillance, closer observation and referral. It is not proposed as a trigger for cooling. Keywords: neonatal encephalopathy; infant cry; acoustic analysis; smartphone; diagnostic accuracy; low-resource setting.
Free Newsletter