Radar and vision dominate non-contact IoT monitoring, but standardized benchmarking remains limitedNon-contact IoT Systems Monitor Heart Rate and Breathing Rates

AI-generated summary of the cited source, checked by automated accuracy review. How we work

Key Takeaway
Consider deployment context when selecting non-contact monitoring modality; standardized performance data are lacking.

This systematic review synthesizes 88 studies on non-contact medical Internet of Things (IoT) systems for monitoring physiological biomarkers such as heart rate, respiration rate, temperature, oxygen saturation, and blood pressure. The authors describe the landscape of sensing modalities, including radar, vision, sound, Wi-Fi, embedded sensors, and mixed designs.

Radar and vision-based systems account for approximately three-quarters of included studies. Respiration rate is the most commonly monitored parameter, appearing in 83% of studies, followed by heart rate in 67%. No other parameter (blood pressure, oxygen saturation, or temperature) exceeds 11% of studies. The review also assessed methodological quality and privacy-preserving mechanisms.

The authors highlight several limitations: heterogeneous reporting metrics prevent direct statistical comparison of performance between modalities; signal reliability in uncontrolled environments is a concern; limited benchmarking exists due to the absence of standardized datasets; and privacy and ethical concerns remain. Poor integration with existing healthcare infrastructure is also noted. A proposed federated, edge-based learning framework is described as a design proposal, not a validated system.

For practice, modality selection should be driven by deployment context: radar for wards and ICUs; vision and sound for structured clinical spaces; embedded sensors for eldercare beds and chairs; and mixed radar and vision for precision-critical settings such as neonatal and postoperative monitoring. However, the lack of standardized performance data means clinicians should interpret these suggestions cautiously.

Researchers reviewed 88 studies to evaluate how non-contact medical Internet of Things (IoT) systems track vital signs. These systems use technologies like radar, vision, sound, and Wi-Fi to monitor patients without physical contact. This type of technology is being explored to track heart rate, breathing rates, body temperature, oxygen levels, and blood pressure.

The review found that radar and vision systems are the most common methods used in current research. Specifically, breathing rates were tracked in 83% of the studies, while heart rates were tracked in 67%. Other metrics, such as blood pressure and oxygen saturation, were much less common in the reviewed studies.

Because these systems are still being developed, there are several hurdles to overcome. The study noted that these tools can struggle in uncontrolled environments and are not yet fully integrated into standard healthcare systems. While promising for specific settings like ICUs or eldercare, the technology is not yet a standard of care. Patients should consult their doctors regarding the best ways to monitor their health.

What this means for you:
Non-contact sensors like radar and vision can monitor heart and breathing rates but are not yet standard care.

Common questions

What types of technology are used for non-contact monitoring?

The review looked at several methods, including radar, vision, sound, Wi-Fi, and embedded sensors. Radar and vision-based systems are the most common, making up about three-quarters of the studies. These methods are being tested to monitor heart rate, respiration rate, temperature, oxygen saturation, and blood pressure.

Which health markers are most commonly tracked by these systems?

Respiration rate is the most common metric, appearing in 83% of the studies. Heart rate appears in 67% of the studies. Other metrics, such as blood pressure, oxygen saturation, and temperature, were much less common, with none appearing in more than 11% of the studies.

Are these systems ready for everyday use in hospitals?

These systems are not yet fully integrated into current healthcare infrastructure. The study noted that signal reliability can be difficult in uncontrolled environments and there are still concerns regarding privacy and ethics. Different settings, like ICUs or eldercare beds, may require different types of sensors.

Study Details

Study typeMeta analysis
EvidenceLevel 1
PublishedOct 2026
View Original Abstract ↓
Non-contact medical Internet of Things systems measure physiological biomarkers such as heart rate (HR), respiration rate (RR), temperature, oxygen saturation (SpO₂), and blood pressure (BP) without physical contact with the patient. These systems combine sensing modalities including cameras, radar, Wi-Fi, acoustic, and infrared sensors with signal processing and learning algorithms to deliver comfortable, non-invasive monitoring. Prior reviews have largely examined individual sensing modalities or signal processing techniques in isolation, leaving cross-modality system architecture and privacy-preserving design underexamined. We conducted a systematic review following PRISMA guidelines and analyzed 88 recent studies of non-contact monitoring systems. Studies were characterized by sensing modality, system architecture, target physiological parameter, validation setting, and reported performance. We additionally assessed each study for methodological quality and examined the extent to which privacy-preserving mechanisms were incorporated into system design. Radar and vision-based systems dominate the corpus, together accounting for approximately three-quarters of included studies, while sound, Wi-Fi, embedded sensor, and mixed-modality designs remain at an earlier stage of validation. Research effort is heavily concentrated on two parameters: RR appears in 83% of studies and HR in 67%, while no other parameter exceeds 11%. BP, SpO₂, and temperature therefore remain largely unaddressed by contactless methods. Heterogeneous reporting metrics across studies prevent direct statistical comparison of performance between modalities. The findings indicate that modality selection should be driven by deployment context rather than headline accuracy. Radar suits wards and intensive care units where patients are covered or moving, vision and sound suit structured clinical spaces with stable conditions, embedded sensor designs suit eldercare beds and chairs, and mixed radar and vision systems suit precision-critical settings such as neonatal and postoperative monitoring. Persistent challenges include signal reliability in uncontrolled environments, limited benchmarking due to the absence of standardized datasets, privacy and ethical concerns, and poor integration with existing healthcare infrastructure. Building on these insights, we propose a conceptual federated, edge-based learning framework, presented as a design proposal for future implementation rather than a validated system, and outline research directions to accelerate clinical translation.