Mode
Text Size
Log in / Sign up
N/A Completed N=70 Randomized Single-blind Treatment

The Clinical Comparison of Narafilcon A and Stenfilcon A Contact Lenses

Source: ClinicalTrials.gov NCT02920970 ↗
Enrolled (actual)
70
Serious AEs
0.0%
Results posted
Jan 2019
Primary outcomePrimary: Ocular Physiology — 0.84; 0.76; 0.75; 0.62 units on a scale

Summary

This study aims to compare the clinical performance and subjective acceptance of the narafilcon A lens with the stenfilcon A lens when used on a daily wear, daily disposable basis.

Outcome Measures

OutcomeResultp-value
PRIMARY
Ocular Physiology
0.84; 0.76; 0.75; 0.62; 0.05; 0.03 —
PRIMARY
Visual Acuity
-0.12; -0.10; 0.17; 0.17 —
PRIMARY
Comfort Level of Stenfilcon A and Narafilcon A Lenses
91.4; 83.1 —
PRIMARY
Dryness of Stenfilcon A and Narafilcon A Lenses
82.1; 81.2 —
PRIMARY
Vision of Stenfilcon A and Narafilcon A Lenses
91.4; 88.4 —
PRIMARY
Lens Surface - Deposition on Stenfilcon A and Narafilcon A Lenses
64; 62; 4; 5; 0; 1 —
PRIMARY
Lens Surface - Wettability of Stenfilcon A and Narafilcon A Lenses
55; 59; 8; 5; 4; 4 —
PRIMARY
Lens Fit - Horizontal Centration of Stenfilcon A and Narafilcon A Lenses
0; 0; 0; 0; 44; 46 —
PRIMARY
Lens Fit - Vertical Centration of Stenfilcon A and Narafilcon A Lenses
0; 0; 11; 12; 42; 48 —
PRIMARY
Lens Fit - Corneal Coverage of Stenfilcon A and Narafilcon A Lenses
0; 0; 4; 2; 56; 60 —
PRIMARY
Lens Movement
0; 0; 3; 5; 55; 54 —

Eligibility Criteria

Inclusion Criteria

  • Subjects will only be eligible for the study if:
  • They are of legal age (18) and capacity to volunteer.
  • They understand their rights as a research subject and are willing and able to sign a Statement of Informed Consent.
  • They are willing and able to follow the protocol.
  • They agree not to participate in other clinical research for the duration of this study.
  • They have a contact lens spherical prescription between -1.00 to - 6.00D (Diopters) (inclusive)
  • They have a spectacle cylindrical correction of -0.75D or less in each eye.
  • They can be satisfactorily fitted with the study lens types.
  • At dispensing, they can attain at least 0.10 logMAR distance high contrast visual acuity in each eye with the study lenses within the available power range.
  • They currently use soft contact lenses or have done so in the previous six months.
  • They are willing to comply with the wear schedule (at least six days per week and for at least eight hours per day).
  • They own a wearable pair of spectacles.

Exclusion Criteria

  • Subjects will not be eligible to take part in the study if:
  • They have an ocular disorder which would normally contra-indicate contact lens wear.
  • They have a systemic disorder which would normally contra-indicate contact lens wear.
  • They are using any topical medication such as eye drops or ointment.
  • They have had cataract surgery.
  • They have had corneal refractive surgery.
  • They have any corneal distortion resulting from previous hard or rigid lens wear or have keratoconus.
  • They are pregnant or breast-feeding.
  • They have any ocular abnormality which would, in the opinion of the investigator, normally contraindicate contact lens wear.
  • They have any infectious disease which would, in the opinion of the investigator, contraindicate contact lens wear or pose a risk to study personnel; or they have any immunosuppressive disease (e.g. HIV), or a history of anaphylaxis or severe allergic reaction.
  • They have taken part in any other contact lens or care solution clinical trial or research, within two weeks prior to starting this study.
  • They currently wear either the stenfilcon A lens or narafilcon A lens.
View full record on ClinicalTrials.gov →

Data sourced from ClinicalTrials.gov (NCT02920970). Outcome figures and adverse-event rates are extracted automatically from the registry's posted results and are provided for clinician reference, not as a substitute for the primary publication. Informational only — not medical advice.

Back to search